Detecting aerosol events caused by nanoparticles
Date published: 2021
Please login or subscribe to view UPM Resources.
This presentation was given as part of the Ultrapure Micro 2021 annual conference. It was given as part of the airborne molecular contamination (AMC) and high purity gases control strand.
Companies: TSI Incorporated;
Authors: Richard Remiarz;
Tags: Nanoparticles; Particle Count and Detection; Airborne Molecular Contamination (AMC)
Related resources
Id | Year | Materials | Info | Company | Author | Tags | View |
---|---|---|---|---|---|---|---|
... | 2021 |
|
Measurement of nanoparticles and their precursorsThis presentation was given as part of the Ultrapure Micro 2021 annual conference. It was given as part of the airborne molecular contamination (AMC) and high purity gases control strand.
|
Airmodus; | Joonas Vanhanen; | Airborne Molecular Contamination (AMC); Nanoparticles; Metrology and Analytical Technology; Particle Precursors; Particle Count and Detection | View |
... | 2021 |
|
Nanoparticles characterisation for semiconductor UPW production system monitoring using ICP-MSThis presentation was given as part of the Ultrapure Micro 2021 annual conference. It was given as part of the ultrapure water strand.
|
Air Liquide; | Jinjin Wang; Fuhe Li | Nanoparticles; UPW System; Metrology and Analytical Technology; Particle Count and Detection | View |
... | 2019 |
|
Profiling nanoparticles down to 10 nm in a UPW polishing system by two different particle countersNanoparticle contamination of ultrapure water (UPW) for microelectronics fabrication is expected to significantly decrease the yield and reliability of semiconductor devices. Tight nanoparticles control poses a technical and analytical challenge, especially in the particle size range down to a few nanometres. Most state-of-the-art online particle counters do not address the needs of advanced microelectronics manufacturing with critical particle sizes below 20 nm. Therefore, understanding of sources of nanoparticle contamination and strategies for control is limited. This study aims to profile nanoparticles ≥10 nm in a full-scale UPW polishing system after each process step using two novel particle measurement systems: an optical particle counter and an acoustic particle counter. For the first time, the performance of a whole UPW polishing system, including a Reverse Osmosis (RO) unit in terms of particle rejection, was investigated. Both particle counter instruments were evaluated with positive results. A statistical analysis was carried out to compare the significance of the particle counts achieved by the two different detection principles. Profiling throughout the UPW polishing system revealed that both instruments measure particle concentrations in the same range. The data is consistent and shows a clear trend: ion exchange mixed bed, Reverse Osmosis (RO) and ultrafiltration remove particles and represent sinks for nanoparticles ≥20 nm. The removal of nanoparticles between 10 nm and 20 nm is limited in this case however, especially for the final ultrafiltration. Scanning electron microscopy (SEM) with elemental analysis demonstrated that the particle chemistry was diverse. This indicates that different particle chemistries and particle properties might have influenced the particle counts. The results contribute to the advanced understanding of nanoparticle behaviour in UPW and provides more confidence in terms of monitoring at the lower particle range. This article was originally published in the Ultrapure Micro Journal in March 2019.
|
Ovivo; Micron; | Pia Herrling; Philippe Rychen; Deena Starkel; Keanan Cassidy | Nanoparticles; Particles; Particle Count and Detection; UPW Polishing | View |
... | 2020 |
|
UPW Contamination Control - Q&AThis Q&A session took place at the 2020 Ultrapure Micro annual conference. It was a part of the Ultrapure Water Production track, and included speakers from the UPW Contamination Control session.
|
Intel; Particle Measuring Systems; Organo; Entegris; | Glen Slayter; Dan Rodier; Kyohei Tsutano; Sid Sampath | Particle Count and Detection; Metal Contamination; Filtration; Nanoparticles | View |
... | 2020 |
|
Critical Particle Monitoring - Q&AThis Q&A session took place at the 2020 Ultrapure Micro annual conference. It was a part of the Ultrapure Water Production track, and included speakers from the Critical Particle Monitoring session.
|
CT Associates; Ovivo; Kanomax FMT; | Gary van Schooneveld; Najib Alia; Derek Oberreit; | Particle Count and Detection; Nanoparticles; Particle Precursors | View |
... | 2020 |
|
Understanding Nanoparticle Contamination in Ultrapure Water Generation and DistributionThis presentation was given at the Ultrapure Micro 2020 annual conference. It was presented in the Ultrapure Water Production track, as part of the UPW Contamination Control session.
|
Intel; Particle Measuring Systems; | Glen Slayter; Dan Rodier; | End-user; Nanoparticles; Particle Count and Detection; Metrology and Analytical Technology; Case Study; UPW Polishing | View |
... | 2020 |
|
Measurement of Particle Precursors in Ultrapure WaterThis presentation was given at the Ultrapure Micro 2020 annual conference. It was presented in the Ultrapure Water Production track, as part of the Critical Particle Monitoring session.
|
CT Associates; | Gary van Schooneveld; Jikku Thomas; | Particle Precursors; Nanoparticles; Particle Count and Detection | View |
... | 2019 |
|
Advanced Microscopy for Quantification and Identification in UPW, Process Chemicals, and Industrial GasesThis presentation was given at the Ultrapure Micro 2019 annual conference. It was presented in the Ultra High Performance Chemicals and High Purity Gases track, as part of the Nanoscale Analytical: PPW? session.
|
Air Liquide; | Fang Li; | Nanoparticles; Metrology and Analytical Technology; Filtration; Particle Count and Detection; High Purity Gases | View |
... | 2019 |
|
Retention Efficiency for sub-30 nm Particles Quantitatively Measured by Single Particle DetectionThis presentation was given at the Ultrapure Micro 2019 annual conference. It was presented in the Ultra High Performance Chemicals and High Purity Gases track, as part of the Nanoscale Analytical: PPW? session.
|
3M; | Charlie Chan; Daniel Lei; Jinsheng Zhou; Majid Entezarian; Robert Gieger | Metrology and Analytical Technology; Nanoparticles; Particle Count and Detection; SEMI | View |
... | 2019 |
|
New Nano and Microparticle Detection, Identification and Monitoring of Fluids Using Nano-Flow Imaging MicroscopyThis presentation was given at the Ultrapure Micro 2019 annual conference. It was presented in the Water Management and Wastewater Treatment track, as part of the New Approaches in Water Management session.
|
Fluid Imaging Technologies, Inc. | Kent Peterson | Particle Count and Detection; Nanoparticles | View |